Construction & Engineering News South Africa

Veolia upgrades pump station in KZN

Contracted by the Newcastle Municipality in KwaZulu-Natal, Veolia Water Technologies South Africa recently upgraded the outdated Ncandu pump station.

Situated 5km from the town, the pump station was unable to meet high sewage capacities, leaving the municipality and downstream industrial businesses with an overloaded sewerage system.

The new pump station features various intelligent systems to alert operators of any malfunction to reduce the chances of pump station failure.
The new pump station features various intelligent systems to alert operators of any malfunction to reduce the chances of pump station failure.

The existing old pumps were prone to tripping and often flooded the pump station, so the first step of the project saw Veolia cleaning the pumping station, situated 15m below ground. This included removing sump, scraping the walls and rehabilitating the existing infrastructure for the new, larger pumps.

Veolia replaced the aged pumps with two new Sulzer pumps, imported from Germany, that were integrated into the existing pipework infrastructure. Sulzer is one of the Veolia Group’s international strategic suppliers for pumps. The two immersible Sulzer XFP high-capacity sump pumps are capable of processing 220l of raw sewage per second at a 27m elevation.

Ensuring system reliability

“The pumps are set at a standby duty configuration to ensure system reliability. This means that when the first pump reaches 60% capacity, the second pump will automatically switch on to ensure demand is met and that no flooding or overflow discharge occurs,” comments Blake Cooley, project engineer at Veolia Water Technologies South Africa. “In addition, this standby configuration also ensures that if either pump malfunctions or requires servicing, it gives the pumping station a four- to eight-hour buffer period before breakdown or overflow.” These Sulzer pumps, however, would continue to operate in the unlikely case of overflow due to their submersible designs.

Early in the installation, the existing pumps failed and flooded the entire pumping station. In addition to cleaning the waste, Veolia installed a temporary T8 pump to ensure that no effluent would be discharged during the installation period. “As this was a live operation, we had to bypass the Ncandu pump station using a temporary solution so that the pumping of the sewage to the wastewater plant could continue,” comments Cooley.

To ensure the maintainability of the pump station, Veolia installed a penstock stainless steel gate to effectively isolate the pumps from each other. This means that when one pump requires cleaning or maintenance, the gate will isolate the sewage flow to the functioning pump only. Prior to this, the operators relied on manually handled sand bags which proved extremely laborious and often ineffective.

Inside Ncandu Pump Station two Sulzer pumps wait to pump 220l of sewage every second.
Inside Ncandu Pump Station two Sulzer pumps wait to pump 220l of sewage every second.

Safety systems

In order to power the two 71kW pumps, Veolia was also contracted to upgrade the transformer and motor control centre (MCC) panels with the help of external instrumentation and control suppliers. “These MCCs provide variable speed and soft-starting pump performance ensuring that their operating capacity matches the sewage demand of the time,” adds Cooley. These intelligent systems will also immediately alert the operator, via SMS, to any potential pump tripping or overloading. Veolia also installed a precautionary 1km air raid siren to alert the operator of pump station overload or failure.

“These safety systems, in addition to our operator training on MCC usage and proper maintenance practices, aim to reduce the chances of any sewage discharge from this pump station in the future,” concludes Cooley.

Veolia repaired and refurbished the existing T6 pumps and returned them to the Newcastle Municipality where they can function in lower-capacity applications. The revamped Ncandu pump station was also designed to accommodate future growth and Veolia completed the required pipework for additional sump pumps as well as made space provisions for a new generator room.

Let's do Biz